W-PFS-008 Premium Fuel Cleaning System
8 litres per minute fuel polishing system, cleaning fuel to 2 micron, removing both free and emulsified water, bacteria and particulate.
This 12vDC or 24vDC unit is available in a range of finishes including wall mounted, enclosure, frame and portable trolley.
Our W-PFS range can be custom built to your specifications and offers medium to high flow fuel cleaning with manual, automatic and BMS (Building Management System) control. Complete monitoring is at your finger tips with our user friendly colour touch screen control system.
For a 200vac power option, see our W-PFS-010 Fuel Polishing Unit.
SUITABLE FOR
Tank sizes up to 10,000 litres, cleaning 8 litres per minute. Available in 12vDC and 24vDC
TOUCH SCREEN CONTROL
Easy to use, manual and auto set up, BMS, reporting and trending, export data, Ethernet desktop sharing and much more.
CLEAN TO 2 MICRON
Including removal of emulsified and free water, bacteria, dirt, and particulate.
FUEL PROTECTION
For data centres, generators, hospitals, marine, agricultural tanks, banking, government, embassies..
Fuel Polishing for 10,000 litre tank
Fuel Polishing for 10,000 litre tank
Trolley mounted
Trolley mounted
Multiple tank cleaning
Multiple tank cleaning
Add-on: Enclosure
Add-on: Enclosure
Add-on: Towing Unit
Add-on: Towing Unit
Only best quality fittings
Only best quality fittings
Example installation
Example installation
Fuel Polishing Results
Fuel Polishing Results
Water contamination
Water contamination
Fuel Tank Contamination
Fuel Tank Contamination
Mobile connectivity
Mobile connectivity
Colour touchscreen as standard
Colour touchscreen as standard
https://www.wasp-pfs.com/products/fuel-polishing-systems/w-pfs/w-pfs-008#sigProId716c081b06
- Advanced, high speed DC system, providing full control system and monitoring
- Manual, Automatic (timer) and BMS (Building Management System) control system
- Fuel conditioning stage for anti-bacterial action, eliminates the build-up of algae and water in your tanks
- Patented centrifugal removal process
- Recirculation or transfer action
- Service filter alarm
- Water in fuel alarm
- Differential alarm
- 99.9 % free water removal in a single pass
- 99 % emulsified water removal in a single pass
- 2 micron final polish/fuel cleaning
- Range of add-on options
This email address is being protected from spambots. You need JavaScript enabled to view it.
![]() |
![]() |
![]() |
|
Wall Mounted |
Enclosure |
Portable |
|
W-PFS-008 8 lit/min Power Options |
12v DC / 24v DC |
12v DC / 24v DC |
12v DC / 24v DC |
Need help selecting the right system for your requirements? Use our new Product Selector.
For more technical information, please see the Technical Details tab.
Model | W-PFS-008-W-24vdc | W-PFS-008-W-12vdc |
---|---|---|
Max flow rate |
8 lit/min flow rate max** |
|
Recommended tank size |
10,000 Litres maximum |
|
Power options |
24v DC |
12v DC |
Finish options |
Wall Mounted, Enclosure, Trolley |
|
Particulate removal to |
2 Micron |
|
Control unit |
Touch screen control |
PLC Control |
BMS (Building Management System) outputs |
6 |
6 |
BMS (Building Management System) inputs |
2 |
2 |
Fuse |
3a |
5a |
Typical current |
3a |
5a |
Suction capability |
1.5m vertical lift, over 5m with non-return valve fitted and when primed |
|
Port sizes |
3/4" BSP |
|
Pump body |
Steel |
|
Pump type |
PTFE Gear |
|
Shaft |
316 Stainless steel |
|
Seal |
Flouoroelastomer |
|
Dimensions * |
700x700x250mm |
|
Weight * |
18KG approx |
*Measurements above are for the wall mounted model.
**Flow rates quoted assume the ideal conditions, a large positive head, no left, wide pipe work, etc. Narrow pipes, tight bends, elbows, lifts and other such external factors can and will impact on the maximum flow achieved by the system.
-
Ensure the system is securely fastened to a wall or other suitable solid structure.
-
The unit should have unique pipe work from any existing fuel driven equipment. The input to the WASP system should feed from the bottom of the fuel tank (via a ball valve and a foot valve or non return valve)
-
The system should pick-up fuel from the lowest point of the tank at one end, (below the level of the fuel feed to your engine) and ideally return it to the highest point at the opposite end.
- The output should return to the tank at the top, opposite end to the input ideally.
- The unit can be controlled via BMS (Building Management System), however it is capable of self operation and monitoring.
- System must be primed before use and operation. It must also be primed after servicing; although with the aforementioned foot or non return valve installed, priming should only need to be done once after installation.
- With power applied, please ensure the system’s time and date have been correctly set.
- We recommend an internal pipe diameter of 3/4” for the 010 model and 1” for the others; however larger diameters will assist the unit as this reduces the frictional losses. Small diameters, long pipe runs or many bends in the pipe work will cause high frictional losses and cause the system to run slower than its maximum speed, or in extreme cases cause it to stop. Likewise high fuel lifts or fuel heads will also cause the unit to run slower.
-
In any typical fuel tank, the pipe feeding fuel to the engine is not at the bottom, however to successfully clean fuel, the pickup pipe going to the WB unit should be right at the bottom of the tank, below the engine feed.
- Full W-PFS Range of products
- W-PFS-010
- W-PFS-014
- W-PFS-026
- W-PFS-040
- W-PFS-060
- W-PFS-120
- W-PFS-240
- W-PFS Range Brochure
- WB Fuel Cleaning Range
- Compare WB and W-PFS
- Use our helpful product selector
- New to fuel polishing?
- How does it work?
- Spare Parts Page
- Product Support
- Download the Protecting your data PDF
Try our helpful new PRODUCT SELECTOR to select the model for your needs.